The slope of the light steel structure roof is generally small, often below 6%. In the rainy areas in Central South, the roof leakage of this structure is more common. There are large areas of water leakage, daylight windows, and drips at the joints of the roof. The reasons are Water leakage is mostly caused by self-tapping screws, lap joints of color steel plates, roof ridge tiles, blind rivets, deformation of color steel plates caused by people on the roof, and rain-proof glue falling off of decorative parts such as daylighting windows.

 

 

Roof air floor position

The main reason for water leakage in this part is: no foam plug is placed under the edge of the air building and roof junction, and no cement or silica gel is laid on the longitudinal overlap of the edge; the outer roof panel is not plated at the air building junction; the structure of the air building The openings of the pillars have not been waterproofed; the production and installation of the gas tower itself has hidden water leakage. The solution is: foam plugs should be laid before the edge is installed, and the longitudinal overlaps must be set with cement or the plugs with suture nails; the roof panels must be installed before the gas tower is installed; the gas tower construction party is required to be after the gas tower structure is completed Waterproof the openings, and check the installation quality and waterproof performance of the gas building.

 

 

Cornice

This part is the main part of water leakage. The main reasons for water leakage are: the outer roof panel is installed without foam plugs, and the outer roof panel is not lowered; the length of the wall outer panel is insufficient, and the cornice is not waterproof. The solution is: when installing the roof outer panel, a foam plug should be placed at the same time, and the roof outer panel should be lowered by 30°, and the cornice should be added with an edge according to the design requirements.

 

Awning part

The main cause of water leakage in this part is: improper handling of the joint 151 between the awning and the attached house; no plug is set between the awning and the external wall or not extending into the external wall panel according to the design requirements. The solution is: the connection 151 between the awning and the attached house must be lapped and waterproofed; under normal circumstances, the 151 flashing side of the awning should enter the outer wall panel. For the convenience of installation and construction, the flooding shall be collected. The side can also be directly against the outer wall of the wall, but a plug must be placed and the gap must be sealed with silica gel.

 

Brick wall and light steel roof connection part

This part is easy to form a hidden danger of water leakage, and the joint between the roof panel and the cement wall leaks. The main reason is that the stress is not synchronized, which causes the silicone glue and the bonding surface to crack and leak. Solution: To prevent temperature deformation, use two edge-receiving connection treatments; when connecting with the brick wall, the edge-receiving should have a certain angle and be completely sealed; sealant should be pre-applied when closing the edge.

 


Copyright:佛山市胜邦钢结构有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粤ICP备13078463号
中央空调木托| 脉冲反吹集尘器| 气体流量传感器| 转盘轴承生产厂家| 生物制药洁净车间| 热强度测定仪| 马弗炉mafulu| 火焰风管光度计| 游艇船舶装修铝蜂窝板| 二维条码检测仪| 单人超净工作台| 进口生物材料试验机| 酸碱废气洗涤塔| 蓄电池活化仪| 重金属水质自动| 中国国际农业机械展览会| STARRETT数显卡尺| 纳米ATO| LED平台灯| 往复式新型脱色摇床| 全自动核酸提取纯化仪| 波形垫圈「厂家」| JAQUET测速仪| Roboz手术剪| 防水涂层测厚仪| 开模定制液晶| 智能阀控器| 悬浮式拼装地板| 管状式加热器| 气体检测仪| 定量包装机| 便携式医用冷藏箱| 电力电缆故障测试仪| 无锡代理记账| 防火门价格| 陶瓷柱塞移液泵| 4300系列压力传感器| 海尔生物医疗四川代理商| 钙蛋白酶试剂盒| 塑料内膜袋| 船用齿轮箱|